Les produits de cette circulaire
INSULATED DRINKING TROUGHS uried at least four ( ground surface or one ding to y stallation on a b with an 18 inc frost ine acc the best performance Insutsted heating tube Frost line > Earthing (must meet your —————ÿ#> regional regulations) —— Frost line Earthing (must meet your regional régulations) Main water line HOW TO INSTALL AN OUTDOOR TROUGH TO KEEP YOUR FARM ANIMALS HYDRATED IN ALL WEATHER Outdoor troughs must be installed methodically. This is not the time to improvisel The water hose running to the outdoor trough must be 1 inch in diameter. This ensures a sufficient and consistent water flow to meet your farm animals’ needs. The water pipe must be installed at least 4 feet underground. We highly recommend digging 1 foot lower than the frost line in your area. The depth of this line varies from region to region, so be Ideally, your outdoor pou should be securely affixed and sheltered from the wind. careful. to a concrete surface (see diagram The water inlet hose must be positioned in the centre of the platform. If you do not use a concrete platform and instead place the trough directly on the ground, it will not be stable enough, and you run the risk of the water hose breaking from repeated contact as the animals drink. We recommend a concrete slab between 4 and 6 inches deep and large enough to cover an 18-inch perimeter around the trough. This way, when Your cows go up to drink, they will place their front hooves on the slab. Because space is limited, they will not be able to put their back hooves on it as well, so when they finish drinking and turn around, they will not risk contaminating the water supply with their excrement ERIAL Polyethyiene TYPE 1X8-3/4-in. (22-cm) opening BALLS 1 X 9-in. (22.8-cm) ball INSULATION Urethane foam DIMENSIONS 21HX26DX28Lin (53X66X 71cm) Ain. (35 cm) 57 L (15 gai) 5ys 25 cows or 50 beef cattle 047-3385 OPTIONA OPTIONA 047-3835 Insulated heating tube 047-3835 BUY ONLINE | bmr.ca Polyethyiene 2X9-1/4-in. (23-cm) openings 2X10-in. (25-cm) balls Polyethylene 1X10-in. (25-cm) opening 1X10-3/4-in. (27-cm) ball Urethane foam INSULATION Urethane foam 18H X 36 LX 24 Din. DIMENSIONS 26-1/2HX29LX 31 Din {5 X 91 X 61 cm) (67X73X 79 cm) 18 in. (45 cm) TROUGH HEIGHT 18 in. (45 cm) 76 L(20 ga) CAP) 112 L (30 gai) Sy WARRANTY 5Sys 40 cows or 100 bee catile RECOM DFOR 30 cows or 75 beefcattle 047-3446 OPTIONAL Insulated heating tube 047-3835 Insulated heating tube 2024 Winter Preparation Guide | Page 2
Nom | Détails |
---|